PRODUCTS

loading

Share to:

Flame-Resistance Cable for Coal Mining

Availability:
Quantity:

3.1 Flexible Mining machine cable for rated voltage upto and including 1.9/3.3kV. 

Executive standard: MT818.2 - 1999 

Operating condition: 

1). Rated voltage Uo/U is 0.38/0.66kV,O.66/1.14kV and 1.9/3.3kV. 

2). Long-term operating temperature allowance of conductor for rated voltage upto and including 0.66/1.14kV is 65℃; Long-term operating temperature of conductor for rated voltage 1.9/3.3kV is 90 ℃. 

3). The min.bending radius should be 6 times of cable outer diameter. Type,Designation and application of cable

Type DesignationApplication
MC-0.38/0.66 Rubber jacket flexible shield cable 
for minning machine
Connected power for minning machine and 
similar equipment rated voltage 
0.38/0.66kV. 
MCP-0.38/0.66 Rubber jacket flexible shield cable 
for minning machine
Connected power for minning machine and 
similar equipment rated voltage 
0.38/0.66kV. 
MCP-0.66/1.14 Rubber jacket flexible shield cable 
for minning machine
Connected power for minning machine and 
similar equipment rated voltage 
0.66/1.14kV. 
MCP-1.9/3.3 Rubber jacket flexible shield cable 
for minning machine
Connected power for minning machine and 
similar equipment rated voltage 
1.39/3.3kV. 


3.2 Rubber jacket shielded controlled flexible minning machine cable rated voltage 0.66/1.14kV 

Executive standard:MT818.3-1999 

Operating condition 

1). Rated voltage Uo/U is 0.66/1.14kV.

2). Long-term operating temperature allowance of conductor is 90℃.

3). The min.bending radius should be 15 times of cable outer diameter. 

Type,Designation and application of cable

TypeDesignationApplication
MCPJB - 0.66/1.14 Rubber jacket shield controlled 
wrapped strength flexible minning 
machine cable
Connected power for minning machine and 
similar equipment rated voltage 
0.38/0.66kV. 
MCPJR - 0.66/1.14 Rubber jacket shield controlled 
wrapped strength flexible minning 
machine cable
Connected power for minning machine and 
similar equipment rated voltage 
0.38/0.66kV. 


3.3 Rubber jacket movable flexible cable for Rated Voltage upto including 0.66/1.14kV

Executive standard:MT818.5—1999 

Operating condition 

1 Fated voltage Uo/U is 0.38/0.66kV and 0.66/1.14kV. 

2.Long-term operating temperatrue allowance of conductor is 65℃ 

3. The min.bending radius Should be 6 times of cable outer diameter. 

Type,Designation and application of cable

TypeDesignationApplication
MY-0.38/0.66Rubber jacket flexible coal 
mining cable for movable type
Connected power for all kinds of movable 
for rated voltage 038/0.66KV
MYP-0.38/0.66Rubber jacket flexible coal 
mining cable for movable type
Connected power for all kinds of movable 
for rated voltage 038/0.66KV
MYP-0.66/1.44Rubber jacket flexible coal 
mining cable for movable type
Connected power for all kinds of movable 
for rated voltage 0.66/1.14KV


3.4 Rubber jacket shielded flexible cable for Rated Voltage upto including 3.6/6kV 

Executive standard:MT818.7—1999 

Operating condition 

1 Fated voltage Uo/U is 1.93/3kV and 3.6/6kV. 

2.Long-term operating temperatrue allowance of conductor is 90℃ 

3. The min.bending radius Should be 6 times of cable outer diameter. 

Type,Designation and application of cable

TypeDesignationApplication
MYPT-1.9/3.3Movable rubber jacket metalled 
shield flexible cable for coal mining
Connected power for winning machine under 
well rated voltage 1.9/3.3KV
MYP-3.6/6Movable rubber jacket shield flexible 
cable for coal mining 
Connected power for minning machine on the 
groung rated voltage 3.6/6KV allowed ambient 
low-temperature is -20
MYPT-3.6/6Movable rubber jacket metalled 
shield flexible cable for coal mining
MYDP-3.6/6Movable rubber jacket shield flexible 
cable for coal mining 
Connected power for minning machine on the 
groung rated voltage 3.6/6KV allowed ambient 
low-temperature is -40
MYDPT-3.6/6Movable rubber jacket metalled 
shield flexible cable for coal mining


3.5 Drill cable for coal mining Rated Voltage 0.3/0.5kV 

Executive standard:MT818.8—1999 

Operating condition 

1 Fated voltage Uo/U is 0.3/0.5kV. 

2.Long-term operating temperatrue allowance of conductor is 65℃ 

3. The min.bending radius Should be 6 times of cable outer diameter.

Type,Designation and application of cable

TypeDesignationApplication
MZ-0.3/0.5Rubber jacket drill cable for coal miningConnected power for drill machine under well rated voltage upto and including 0.3/0.5kV
MZP-0.3/0.5Rubber jacket shield drill cable for coal mining


3.6 Light type movable flexible cable for coal mining 

Executive standard:MT818.9—1999 

Operating condition 

1 Fated voltage Uo/U is0.3/0.5kV. 

2.Long-term operating temperatrue allowance of conductor is 65℃ 

3. The min.bending radius Should be 6 times of cable outer diameter. 

Type,Designation and application of cable

TypeDesignationApplication
MYQ-0.3/0.5Light type movable rubber jacketed soft cable for coal miningConnected power lighting routing machine and signal equipment under well


Previous: 
Next: 

Contact us

Menu

Cables

Contact Us

admin@renmincable.com.cn

Room 1203, Building 4, East International Plaza, No. 85 Jinshui Road, Zhengdong New Area, Zhengzhou City, Henan Province, Zhengzhou, Henan, China

Visitors

39434
12345
3456
3002
2212
234

Copyright © 1987-2020 People’s Cable Group Co.,Ltd.