Availability: | |
---|---|
Quantity: | |
Introduction
PVC insulated power cables for rated voltages up to 0.6/1 kV are fit for AC 50Hz distribution lines for the same rated voltages. The mechanical and electrical properties of these cables are accordant with GB/T12706—2008 ( Power
cables extruded insulation and their accessories of rated voltagesl kV(Umz1.2kV)up to ) and IEC-60502—1 :2004 ( Extruded insulation power cables and appendites for rated voltages 1kV up to 30kV)
Instruction of Application
1. Rated Voltage: 0.6/1kV
2. Max.permissible operating temperature of conductor is 90℃.
3. Conductor short-circuit temperature shall not exceed 250℃ Max. sustaining period shall not exceed 5 seconds.
4. Bending Radius
Bending radius of single core cable:20(D+d)±5%
Bending radius of multi core cable:15(D+d)±5%
D-Actual outer diameter of cable sample(mm);
d-Actual diameter of the conductor(mm).
5. No restriction of level difference along the route for installation.
6. Installation temperature shall be heated when ambient temperature is below 0℃
Production Range of PVC Insulated Power Cable
Type | Description | Application |
VV VLV | PVC insulated PVC sheathed power cable | For laying in doors,inducts and in tunnels,but unable to bear pressure and external mechanial forces |
VV22 VLV22 | PVC insulated steel tape armoured PVC sheathed power cable | For laying in doors, in tunnels and direct in ground, able to bearpressure and external mechanial forces |
VV32 VLV32 | PVC insulated thin steel wire armoured PVC sheathed power cable | For laying in doors,in wells,under water,able to bear overlain axis pulling force. |
VV42 VLV42 | PVC insulated thick steel wire armoured PVC sheathed power cable | For laying down wells and under water,able to bear certain pulling force. |
NH ZR-VV ZR-VLV | PVC insulated PVC sheathed flame fire power cable | For laying in doors,inducts and in tunnels,but unable to bear pullingforce and pressure. On the sites where fire occurs freequently. |
NH ZR-VV22 ZR-VLV22 | PVC insulated steel tape armoured PVC sheathed flame fireretardant power cable | For laying in doors,in tunnels and direct in ground, able to bear pulling force and pressure. On the sites where fire occurs freequently. |
NH ZR-VV32 ZR-VLV32 | PVC insulated thin steel wire armoured PVC sheathed flame fireretardant power cable | For laying in doors,in wells,under water,able to bear overlain axis pulling force. On the sites where fire oc- freequently course. |
NH ZR-VV42 ZR-VLV42 | PVC insulated thick steel wire armoured PVC sheathed flame fireretardant power cable | For laying down wells and under water,able to bear certain pulling force. On the sites where fire occurs freequently. |
Structure of Cable
Introduction
PVC insulated power cables for rated voltages up to 0.6/1 kV are fit for AC 50Hz distribution lines for the same rated voltages. The mechanical and electrical properties of these cables are accordant with GB/T12706—2008 ( Power
cables extruded insulation and their accessories of rated voltagesl kV(Umz1.2kV)up to ) and IEC-60502—1 :2004 ( Extruded insulation power cables and appendites for rated voltages 1kV up to 30kV)
Instruction of Application
1. Rated Voltage: 0.6/1kV
2. Max.permissible operating temperature of conductor is 90℃.
3. Conductor short-circuit temperature shall not exceed 250℃ Max. sustaining period shall not exceed 5 seconds.
4. Bending Radius
Bending radius of single core cable:20(D+d)±5%
Bending radius of multi core cable:15(D+d)±5%
D-Actual outer diameter of cable sample(mm);
d-Actual diameter of the conductor(mm).
5. No restriction of level difference along the route for installation.
6. Installation temperature shall be heated when ambient temperature is below 0℃
Production Range of PVC Insulated Power Cable
Type | Description | Application |
VV VLV | PVC insulated PVC sheathed power cable | For laying in doors,inducts and in tunnels,but unable to bear pressure and external mechanial forces |
VV22 VLV22 | PVC insulated steel tape armoured PVC sheathed power cable | For laying in doors, in tunnels and direct in ground, able to bearpressure and external mechanial forces |
VV32 VLV32 | PVC insulated thin steel wire armoured PVC sheathed power cable | For laying in doors,in wells,under water,able to bear overlain axis pulling force. |
VV42 VLV42 | PVC insulated thick steel wire armoured PVC sheathed power cable | For laying down wells and under water,able to bear certain pulling force. |
NH ZR-VV ZR-VLV | PVC insulated PVC sheathed flame fire power cable | For laying in doors,inducts and in tunnels,but unable to bear pullingforce and pressure. On the sites where fire occurs freequently. |
NH ZR-VV22 ZR-VLV22 | PVC insulated steel tape armoured PVC sheathed flame fireretardant power cable | For laying in doors,in tunnels and direct in ground, able to bear pulling force and pressure. On the sites where fire occurs freequently. |
NH ZR-VV32 ZR-VLV32 | PVC insulated thin steel wire armoured PVC sheathed flame fireretardant power cable | For laying in doors,in wells,under water,able to bear overlain axis pulling force. On the sites where fire oc- freequently course. |
NH ZR-VV42 ZR-VLV42 | PVC insulated thick steel wire armoured PVC sheathed flame fireretardant power cable | For laying down wells and under water,able to bear certain pulling force. On the sites where fire occurs freequently. |
Structure of Cable
Room 1203, Building 4, East International Plaza, No. 85 Jinshui Road, Zhengdong New Area, Zhengzhou City, Henan Province, Zhengzhou, Henan, China
Visitors
Copyright © 1987-2020 People’s Cable Group Co.,Ltd.