PRODUCTS

loading

Share to:

0.6/1kV N2XY Copper Conductor XLPE Insulation Power Cable

  • YJV / N2XY
  • RMJT
Availability:
Quantity:

0.6/1kV N2XY Copper Conductor XLPE Insulation Power Cable


Introduction of N2XY Copper Conductor XLPE Insulation Power Cable

XLPE insulated power cables for rated voltages up to 0.6/1 kV are fit for AC 50Hz distribution lines for the same rated voltages. The mechanical and electrical properties of these cables are accordant with GB/T12706—2008 ( Power 

cables extruded insulation and their accessories of rated voltagesl kV(Umz1.2kV)up to ) and IEC-60502—1 :2004 ( Extruded insulation power cables and appendites for rated voltages 1kV up to 30kV) 


Instruction of Application

1. Rated Voltage: 0.6/1kV 

2. Max.permissible operating temperature of conductor is 90℃.

3. Conductor short-circuit temperature shall not exceed 250℃ Max. sustaining period shall not exceed 5 seconds.

4. Bending Radius

     Bending radius of single core cable:20(D+d)±5%

     Bending radius of multi core cable:15(D+d)±5%

     D-Actual outer diameter of cable sample(mm);

      d-Actual diameter of the conductor(mm).

5. No restriction of level difference along the route for installation.

6. Installation temperature shall be heated when ambient temperature is below 0℃


Production Range of XLPE Insulated Power Cable

Type

Description

Scope of Application

YJV

YJLV

Z(K)-YJV

Z(K)-YJLV

Cu or AI conductor XLPE insulated PVC sheathed power cable

Installed indoors or outdoors. In case unable to bear external   mechanical forces but tractive force during laying, single core cable in   magnetic duct is not permissible.

YJV22

YJLV22

Z(K)-YJV22

Z(K)-YJLV22

Cu or AI Conductor XLPE Insulated PVC Sheathed Steel Tape Armoured Power   Cable

For laying in ground able to bear external mechanical forces, but unable   to bear large pulling force.

YJV32

YJLV32

Z(K)-YJV32

Z(K)-YJLV32

Cu or AI Conductor   XLPE Insulated PVC Sheathed Fine Steel Wire Armoured Power Cable

For laying in water or   able to bear external mechanical forces and equal pulling force.


Structure of N2XY Copper Conductor XLPE Insulation Power Cable

5


The main technique performance of N2XY Copper Conductor XLPE Insulation Power Cable

Maximum DC resistance of cable conductor at 20℃

Rated cross area(mm2

0.5

0.75

1.0

1.5

2.5

4

6

10

Cu(Ω/km)

Non tinned   

36.0

24.5

18.1

12.1

7.41

4.61

3.08

1.83

Tinned

36.7

24.8

18.2

12.2

7.56

4.70

3.11

1.84

Al  (Ω/km)

/

/

/

18.1

12.1

7.41

4.61

3.08

Rated cross area(mm2

16

25

35

50

70

95

120

150

Cu (Ω/km)

Non tinned

1.15

0.727

0.524

0.387

0.268

0.193

0.153

0.124

Tinned

1.16

0.734

0.529

0.391

0.270

0.195

0.154

0.126

Al (Ω/km)

1.91

1.20

0.868

0.641

0.443

0.320

0.253

0.206

Rated cross area(mm2

185

240

300

400

500

630

800

1000

Cu  (Ω/km)

Non tinned   

0.0991

0.0754

0.0601

0.0470

0.0366

0.0283

0.0221

0.0176

Tinned

0.100

0.0762

0.0607

0.0475

0.0369

0.0286

0.0224

0.0177

Al ( Ω/km)

0.164

0.125

0.100

0.0778

0.0605

0.0469

0.0367

0.0291


Approximate size & weight of N2XY Copper Conductor XLPE Insulation Power Cable


Single-core of N2XY Copper Conductor XLPE Insulation Power Cable

Normal   cross-sectional area of conductor Overall diameter   of conductor Normal thickness   of insulation Normal thickness   of sheath Approx.
overall diameter
Approx.  weight
mm² mm mm mm mm kg/km
1.5 1.38 0.7 1.4 6 47
2.5 1.78 0.7 1.4 6 59
4 2.25 0.7 1.4 7 77
6 2.76 0.7 1.4 7 99
10 4.05 0.7 1.4 8 147
16 5.01 0.7 1.4 9 209
25 6.0 0.9 1.4 11 304
35 7.0 0.9 1.4 12 400
50 8.1 1.0 1.4 13 524
70 9.9 1.1 1.4 15 732
95 11.5 1.1 1.5 17 991
120 12.9 1.2 1.5 18 1230
150 14.3 1.4 1.6 20 1516
185 16.0 1.6 1.7 23 1890
240 18.4 1.7 1.8 26 2454
300 20.6 1.8 1.8 28 3041
400 23.3 2.0 2.0 32 3888
500 26.7 2.2 2.1 36 4959
630 30.4 2.4 2.2 40 6348

Two-core of N2XY Copper Conductor XLPE Insulation Power Cable


Normal   cross-sectional area of conductor Overall diameter   of conductor Normal thickness   of insulation Normal thickness   of sheath

Approx

.overall diameter

Approx.  weight   
mm² mm mm mm mm kg/km
2*1.5 1.38 0.7 1.8 10 105
2*2.5 1.78 0.7 1.8 10 134
2*4 2.25 0.7 1.8 11 173
2*6 2.76 0.7 1.8 12 226
2*10 4.05 0.7 1.8 15 342
2*16 5.01 0.7 1.8 17 488
2*25 6.0 0.9 1.8 21 711
2*35 7.0 0.9 1.8 23 927
2*50 5.41 1.0 1.8 21 1096
2*70 6.58 1.1 1.8 23 1518
2*95 7.77 1.1 2.0 27 2061
2*120 8.75 1.2 2.1 29 2567
2*150 9.71 1.4 2.2 32 3155
2*185 10.97 1.6 2.3 36 3913

Three-core of N2XY Copper Conductor XLPE Insulation Power Cable


Normal   cross-sectional area of conductor Overall diameter   of conductor Normal thickness   of insulation Normal thickness   of sheath Approx.
overall diameter
Approx.   weight  
mm² mm mm mm mm kg/km
3*1.5 1.38 0.7 1.8 10 127
3*2.5 1.78 0.7 1.8 11 167
3*4 2.25 0.7 1.8 12 221
3*6 2.76 0.7 1.8 13 293
3*10 4.05 0.7 1.8 16 445
3*16 5.01 0.7 1.8 18 647
3*25 6.0 0.9 1.8 22 959
3*35 7.0 0.9 1.8 24 1274
3*50 6.81 1.0 1.8 24 1590
3*70 8.23 1.1 1.8 28 2228
3*95 9.71 1.1 2.0 31 3015
3*120 10.95 1.2 2.1 34 3763
3*150 12.16 1.4 2.3 38 4965
3*185 13.61 1.6 2.4 42 5778
3*240 15.65 1.7 2.6 47 7513
3*300 17.53 1.8 2.8 52 9402

3+1 core of N2XY Copper Conductor XLPE Insulation Power Cable


Normal   cross-sectional area of conductor Overall diameter   of conductor Normal thickness   of insulation Normal thickness   of sheath Approx.
overall diameter
Approx. weight
mm² mm mm mm mm kg/km
3*4+1*2.5 2.25 0.7 1.8 13 258
3*6+1*4 2.76 0.7 1.8 14 344
3*10+1*6 4.05 0.7 1.8 17 516
3*16+1*10 5.01 0.7 1.8 19 765
3*25+1*16 6.0 0.9 1.8 23 1134
3*35+1*16 7.0 0.9 1.8 25 1431
3*50+1*25 6.81 1.0 1.8 27 1863
3*70+1*35 8.23 1.1 1.9 30 2604
3*95+1*50 9.71 1.1 2.1 35 3527
3*120+1*70 10.95 1.2 2.2 38 4489
3*150+1*70 12.16 1.4 2.3 42 5362
3*185+1*95 13.61 1.6 2.5 47 6770
3*240+1*120 15.65 1.7 2.7 52 8743
3*300+1*150 17.53 1.8 2.9 57 10878

Four-core of N2XY Copper Conductor XLPE Insulation Power Cable



Normal   cross-sectional area of conductor Overall diameter   of conductor Normal thickness   of insulation Normal thickness   of sheath Approx.
    overall diameter
Approx. weight 
mm² mm mm mm mm kg/km
4*1.5 1.38 0.7 1.8 11 153
4*2.5 1.78 0.7 1.8 12 204
4*4 2.25 0.7 1.8 13 274
4*6 2.76 0.7 1.8 14 363
4*10 4.05 0.7 1.8 17 559
4*16 5.01 0.7 1.8 20 815
4*25 6.0 0.9 1.8 25 1208
4*35 7.0 0.9 1.8 27 1612
4*50 7.77 1.0 1.9 28 2057
4*70 9.36 1.1 2.0 32 2883
4*95 11.03 1.1 2.1 36 3914
4*120 12.55 1.2 2.3 39 4902
4*150 15.94 1.4 2.4 44 6033
4*185 15.59 1.6 2.6 48 7526
4*240 17.6 1.7 2.8 54 9781
4*300 19.96 1.8 3.0 60 12184

3+2 core of N2XY Copper Conductor XLPE Insulation Power Cable


Normal   cross-sectional area of conductor Overall diameter   of conductor Normal thickness   of insulation Normal thickness   of sheath Approx.
overall diameter
Approx.weight
mm² mm mm mm mm kg/km
3*4+2*1.5 2.25 0.7 1.8 13 294
3*6+2*4 2.76 0.7 1.8 15 399
3*10+2*6 4.05 0.7 1.8 17 589
3*16+2*10 5.01 0.7 1.8 21 879
3*25+2*16 6.0 0.9 1.8 24 1313
3*35+2*16 7.0 0.9 1.8 26 1607
3*50+2*25 8.1 1.0 1.9 30 2243
3*70+2*35 9.9 1.1 2.0 35 3126
3*95+2*50 11.5 1.1 2.1 39 4207
3*120+2*70 12.9 1.2 2.3 44 5303
3*150+2*70 14.3 1.4 2.4 48 6209
3*185+2*95 16.0 1.6 2.6 53 7898
3*240+2*120 18.4 1.7 2.8 60 10188
3*300+2*150 20.6 1.8 3.0 66 12675

4+1 core of N2XY Copper Conductor XLPE Insulation Power Cable


Normal   cross-sectional area of conductor Overall diameter   of conductor Normal thickness   of insulation Normal thickness   of sheath Approx.
overall diameter
Approx. weight  
mm² mm mm mm mm kg/km
4*4+1*2.5 2.25 0.7 1.8 14 313
4*6+1*4 2.76 0.7 1.8 15 448
4*10+1*6 4.05 0.7 1.8 17 656
4*16+1*10 5.01 0.7 1.8 21 946
4*25+1*16 6.0 0.9 1.8 25 1408
4*35+1*16 7.0 0.9 1.8 27 1807
4*50+1*25 8.1 1.0 1.9 32 2479
4*70+1*35 9.9 1.1 2.1 37 3483
4*95+1*50 11.5 1.1 2.2 41 4677
4*120+1*70 12.9 1.2 2.4 46 5791
4*150+1*70 14.3 1.4 2.5 50 7021
4*185+1*95 16.0 1.6 2.7 56 8858
4*240+1*120 18.4 1.7 2.9 63 11473
4*300+1*150 20.6 1.8 3.1 70 14275

5 core of N2XY Copper Conductor XLPE Insulation Power Cable


Normal   cross-sectional area of conductor Overall diameter   of conductor Normal thickness   of insulation Normal thickness   of sheath Approx.
    overall diameter
Approx. weight  
mm² mm mm mm mm kg/km
5*4 2.25 0.7 1.8 14 332
5*6 2.76 0.7 1.8 15 446
5*10 4.05 0.7 1.8 19 691
5*16 5.01 0.7 1.8 22 1007
5*25 6.0 0.9 1.8 25 1504
5*35 7.0 0.9 1.8 28 2007
5*50 8.1 1.0 2.0 33 2726
5*70 9.9 1.1 2.1 37 3823
5*95 11.5 1.1 2.3 43 5190
5*120 12.9 1.2 2.4 48 6349
5*150 14.3 1.4 2.6 53 7869
5*185 16.0 1.6 2.8 59 9788
5*240 18.4 1.7 3.0 67 12849
5*300 20.6 1.8 3.2 74 15920


The power cable current capacity of 0.6/1kV N2XY Copper Conductor XLPE Insulation Power Cable

Apply the model number: YJV(N2XY)  YJLV(NA2XY)              

Limit the term:Environment temperature:400C;: Soil  temperature:250C; Soil thermal receptivity: 2000C·cm/W


Conductor

Area

mm2

The long-term admission current-carrying capacity in   air(A)

The long-term admission current-carrying   capacity in soil(A)

Copper core cable

Aluminum core cable

Copper core cable

Aluminum core cable

1-core

3 or 4

core

1-core

3 or 4  

core

1-core

3 or 4

core

1-core

3 or 4  

core

2.5

34

32

27

25

36

32

27

25

4

44

41

35

32

47

41

35

32

6

56

52

45

42

59

52

46

42

10

77

70

60

53

78

69

59

53

16

100

91

78

70

102

90

77

71

25

132

118

102

91

130

117

104

91

35

164

150

127

114

169

143

117

113

50

196

182

 152

146

187

169

139

134

70

251

228

195

178

226

208

174

165

95

305

273

236

214

269

247

208

195

120

351

314

272

246

300

282

239

221

150

401

360

311

278

339

321

269

247

185

461

410

359

319

382

356

300

278

240

546

483

424

378

435

408

348

321

300

611

552

474

419

495

469

391

365

400

716

/

546

/

574

/

456

/


Previous: 
Next: 

Contact us

Menu

Cables

Contact Us

admin@renmincable.com.cn

Room 1203, Building 4, East International Plaza, No. 85 Jinshui Road, Zhengdong New Area, Zhengzhou City, Henan Province, Zhengzhou, Henan, China

Visitors

39434
12345
3456
3002
2212
234

Copyright © 1987-2020 People’s Cable Group Co.,Ltd.